Setting the paper width ( a = 3) can be changed by Memory switch setting mode
by the panel switch operation when the power supply is turned on.
[Notes] This function works only in user setting mode.
Customized value is specified by unit of 3 bytes ( a, nL, nH)
Ex: A transmitted data as specifying paper width;
ASCII: GS ( E pL pH fn a nL nH
Hexadecimal: 1D 2B 45 04 00 05 03 06 00
Decimal: 29 40 69 4 0 5 3 6 0
To activate the customized values you set with this function, you must
transmit a Function 2 command.
If you attempt to set a combination of settings that is not possible, the NV bit
image memory setting is reduced to an allowable value.
5-595-58
GS ( E pL pH fn [a1 n1L n1H]...[ak nkL nkH] <Function 5>
[Format] ASCII GS ( E pL pH fn [a1n1L n1H] ... [ak nkL nkH]
Hex 1D 28 45 pL pH 05 [a1 n1L n1H] ... [ak nkL nkH]
Decimal 29 40 69 pL pH 5 [a1 n1L n1H] ... [ak nkL nkH]
[Range] 4 (pL + pH x 256) 65533
(0 pL 255, 0 pH 255: (pL + pH x 256) = 3 x k + 1)
fn = 5
1 k 21844
a = 3
nL + nH x 256 = 2, 4, 5 ( nL = 2, 4, 5, nH = 0)
[Default] (nL + nH x 256) = 5 ( nL = 5, nH = 0) [default value when a = 3]
[Description] Changes the customized value specified by parameter a to (nL + nH x 256).
GS ( E pL pH fn a <Function 6>
[Format] ASCII GS ( E pL pH fn a
Hex 1D 28 45 02 00 06 a
Decimal 29 40 69 2 0 6 a
[Range] (pL + pH x 256) = 2 ( pL = 2, pH = 0)
fn = 6
a = 3
[Description] The printer transmits to the host the customized value for the NV memory
area specified by parameter a.
[Notes] This function works both in user setting mode and during normal printer
operation.
The printer transmits the data below ( Header to NUL ) with this function:
a
3
Type of customized value
Paper width
(nL + nH x 256)
2
4
5
Paper width
57.5 mm (2.26 inch)
69.5 mm (2.74 inch)
76 mm (3.00 inch)
paper width settings ( a = 3)
a
3
Type of customized value
Paper width
(*1) The decimal value for the customized value number (a; parameter of this
function) is converted to ASCII character data and sent starting from the
high order end.
Example:
If the a is 118, the 118 (expressed hexadecimally as 31H, 31H, 38H.
Decimally as 49, 49, 56) is converted to 3-bytes data.
(*2) The customized value is determined by the value defined in Function 5.
Example 1:
When setting value is 120, the customized value is 120 expressed with 3
bytes of data (hex numbers: 31H,32H, 30H / decimal numbers: 49, 50, 48).
Example 2:
When setting value is -1, the customized value is 65535 expressed with 5
bytes of data (hex numbers: 36H,35H, 35H, 33H, 35H / decimal numbers:
54,53, 53, 51, 53).
Transmit data
Header
Identifier
Value number (*1)
Hex
37H
21H
30H or 31H
Decimal
55
33
48 ~ 49
Data quantity
1 byte
1 byte
1-3 byte
Transmit data
Separation code
Setting value
NUL
Hex
1FH
30H ~ 39H
00H
Decimal
31
48 ~ 59
0
Data quantity
1 byte
1-5 byte
1-3 byte
CONTROL COMMANDS LIST