5-45
[Description] Stores data ( d1... dk) in the record specified by parameters c1 and c2
(the key code ID numbers).
- When the specified record already exists, the data is overwritten.
- A terminator is automatically assigned.
[Notes] - This command is valid only at the beginning of the line.
- This function uses the "data quantity (k) + 3 byte" area for execution.
- You cannot use this command when the NV user memory does not have
enough capacity to store the specified records.
The available capacity is confirmed by Function 4.
5-44
GS ( C pL pH m fn b c1 c2 <Function 0>
[Format] ASCII GS ( C pL pH m fn b c1 c2
Hex 1D 28 43 05 00 00 fn 00 c1 c2
Decimal 29 40 67 5 0 0 fn 0 c1 c2
[Range] (pL + pHx256) = 5 (pL = 5, pH = 0)
m = 0 fn = 0, 48
b = 0
32 ≤ c1 ≤ 126
32 ≤ c2 ≤ 126
[Description] Deletes the specified record stored in the NV user memory.
The deleted area becomes an "unused" area available for storage.
[Notes] - This command is valid only at the beginning of the line.
- You cannot include macros with this command, so do not use this command
while defining macros.
GS ( C pL pH m fn b c1 c2 d1...dk <Function 1>
[Format] ASCII GS ( C pL pH m fn b c1 c2 d1...dk
Hex 1D 28 43 pL pH 00 fn 00 c1 c2 d1...dk
Decimal 29 40 67 pL pH 0 fn 0 c1 c2 d1...dk
[Range] 6 ≤ (pL + pH x 256) ≤ 65535 (0 ≤ pL ≤ 255, 0 ≤ pH ≤ 255)
m = 0
fn = 1, 49
b = 0
32 ≤ c1 ≤ 126
32 ≤ c2 ≤ 126
32 ≤ d ≤254
k = (pL + pHx 256) -5
GS ( C pL pH m fn b c1 c2 <Function 2>
[Format] ASCII GS ( C pL pH m fn b c1 c2
Hex 1D 28 43 05 00 00 fn 00 c1 c2
Decimal 29 40 67 5 0 0 fn 0 c1 c2
[Range] (pL + pHx 256) = 5 ( pL = 5, pH = 0)
m = 0
fn = 2, 50
b = 0
32 ≤ c1 ≤ 126
32 ≤ c2 ≤ 126
[Description] Transmits the data for the record with the ID code specified by parameters c1,
c2 in the NV user memory.
- ESC/POS Handshaking Protocol is required for this function.
CONTROL COMMANDS LIST
CHAPTER 5