Alarm Record
Record in Alarm Occurrence
There is an alarm input terminal (ALARM IN) on the external I/O port at the back panel of
the DVR COMBO system. Connect here the alarm output terminal of an external device,
such as Multiplexer. (For detailed information on connections, please refer to “3. System
Connection for Alarm Recording” on p. 2-3.) Next, set the ALARM SIGNAL DETEC-
TION of the ALARM RECORD SETUP menu to ON to begin recording whenever alarm
is triggered. Also, set the MOTION DETECTION of the ALARM RECORD SETUP
menu to ON to begin the alarm recording whenever a motion is detected within the area set
in the SET AREA & SENSITIVITY.
Release of Alarm Record
If the system is not in the alarm recording mode, in order to cancel the alarm recording
mode, set the ALARM SIGNAL DETECTION and MOTION DETECTION of the
ALARM RECORD SETUP menu to OFF. To force stop the recording during the record-
ing started by an alarm, press and hold the STOP(
) button for 3 seconds. Then, the record-
ing by the current alarm will be stoppted, and the alarm recording will not be performed for
the next 5 seconds even if alarm occurs. To completely stop the alarm recording, go into the
menu within those 5 seconds to set the ALARM SIGNAL DETECTION to OFF. If no
action is performed by the user for 5 seconds, the system returns to the alarm recording
mode.