DIGITAL VIDEO RECORDER
➄ PRE ALARM TIME LIMIT
The pre-alarm recording is an important function which enables you to find out about the situation
immediately before a motion is detected in the input video or before alarm occurs. Set how much
video data you want to record before the motion is detected or alarm is triggered. About 2 seconds
to 10 seconds of video data are stored in the system’s SDRAM at all times. When a motion is detect-
ed or alarm is triggered, as much data as it is set in the PRE ALARM TIME LIMIT is taken from
the SDRAM and written to the HDD as it simultaneously begins the alarm recording. However, since
the capacity of the SDRAM is limited, the field rate of the pre-alarm recording will decrease as the
time set in the PRE ALARM TIME LIMIT is increased.
[10SECOND/8SECOND/6SECOND/4SECOND/2SECOND/OFF]
➅ POST ALARM TIME LIMIT
Set the amount of video data you want to record immediately after a motion is detected in
the input video or alarm is triggered. The system records as long as the time set in the
MAIN ALARM TIME, and then records more data as long as the time set in the POST
ALARM TIME LIMIT.
[5MINUTE/4MINUTE/3MINUTE/2MINUTE/1MINUTE/30SECOND/20SECOND/
10SECOND/OFF]
➆ MAIN ALARM PICTURE RATE
Set the main alarm recording field rate.
(SCR-3000P models supports recording from 0.50 FPS (Fields Per Second) up to 50 FPS)
● SCR-3000N/SSC-Dual (NTSC)
[60.00FPS/30.00FPS/15.00FPS/10.00FPS/7.50FPS/5.00FPS/2.50FPS/1.00FPS/
0.50FPS]
● SCR-3000P (PAL)
[50.00FPS/25.00FPS/12.50FPS/8.33FPS/6.25FPS/5.00FPS/2.50FPS/1.00FPS/
0.50FPS]
Caution
Caution
If the system is currently recording, the PRE ALARM TIME LIMIT settings will not be
applied even when alarm occurs. The PRE ALARM TIME LIMIT settings are applied
only if the system is not currently recording.
Note
Note
The following illustrates the temporal relationship among the main alarm recording
time (MAIN ALARM TIME), pre-alarm recording time (PRE ALARM TIME LIMIT), and
post alarm recording time (POST ALARM TIME LIMIT) based on the time of alarm
occurrence.
Alarm Occurrence
PRE ALARM TIME LIMIT MAIN ALARM TIME POST ALARM TIME LIMIT