Page 31 of 97 Report No. 236145
TRF No. IEC60335_2_40F
IEC 60335-2-40
Clause Requirement – Test Result Verdict
22.9 Insulation, internal wiring, windings, commutators
and slip rings not exposed to oil, grease or similar
substances
Not exposed to oil, grease or
similar substances.
P
Adequate insulating properties of oil or grease to
which insulation is exposed
N/A
22.10 Not possible to reset voltage-maintained
non-self-resetting thermal cut-outs by the operation
of an automatic switching device incorporated within
the appliance (IEC 60335-1/A1)
No such components. N/A
Non-self resetting thermal motor protectors have a
trip-free action, unless (IEC 60335-1/A1)
Self resetting thermal motor
protectors.
N/A
they are voltage maintained (IEC 60335-1/A1)
N/A
Location or protection of reset buttons of
non-self-resetting controls is so that accidental
resetting is unlikely (IEC 60335-1/A1)
No reset button. N/A
22.11 Reliable fixing of non-detachable parts that provide
the necessary degree of protection against electric
shock, moisture or contact with moving parts
Fixed in a reliable manner by
metal screws, and adequate to
withstand the mechanical
stress.
P
Obvious locked position of snap-in devices used for
fixing such parts
P
No deterioration of the fixing properties of snap-in
devices used in parts that are likely to be removed
during installation or servicing
P
Tests as described
50 N. P
22.12 Handles, knobs etc. fixed in a reliable manner
No such parts. N/A
Fixing in wrong position of handles, knobs etc.
indicating position of switches or similar components
not possible
N/A
Axial force 15 N applied to parts, the shape being so
that an axial pull is unlikely to be applied
N/A
Axial force 30 N applied to parts, the shape being so
that an axial pull is likely to be applied
N/A
22.13 Unlikely that handles, when gripped as in normal
use, make the operators hand touch parts having a
temperature rise exceeding the value specified for
handles which are held for short periods only
No such parts. N/A
22.14 No ragged or sharp edges creating a hazard for the
user in normal use, or during user maintenance
No ragged or sharp edges
creating a hazard for the user
in normal use.
Cooling fins are allowed to be
used for its function.
P
No exposed pointed ends of self tapping screws etc.,
liable to be touched by the user in normal use or
during user maintenance
No exposed pointed ends of
self tapping screws etc.
P