installation part _41
Spring
1. Perform bending of the pipe using the bender which has a
specified bending radius.
2. Be sure to take full care to perform bending of the pipe
successfully at one time. Bending and unbending the pipe
more than twice makes the bending work increasingly difficult.
3. You may use the spring inserted into the gas pipe instead of the
bender to bend the pipe.
4. When you bend the pipe using the spring, hold the pipe with
both hands to prevent any distortion, and secure a minimum
bending radius of more than 100mm.
Pipe Bending
Tightening of Connection Parts
Align the pipes to be connected and tighten the flare nuts
first manually and then with a torque wrench, applying the
following torque.
Outer Diameter Torque (kgf•cm)
ø 9.52mm 250~280
ø 15.88mm 440~480
You can avoid of gas leakage by applying refrigerant oil on
the flare connection part.
Flare connection part
Pipe
Nut
Drilling a Hole in the Wall
Drill a hole of 60mm in diameter to the outside.
The drilling should be done at a distance of less than
150mm from the floor facing the indoor unit.
If a hole on the wall is above 150mm from the floor, use a
hole for drain hose (ø35mm) for connecting drain hose.
Ø 60mm
Less than
150mm
720mm
Hole for drain hose
AP36M0A_IBIM_E_DB98-33839A-1.indd 41 2011-06-10 오후 1:38:07