© 2004 Oasis Imaging Products, Inc. Page 4 of 4
Remanufacturing Instructions
Samsung ML 1710/1750 Toner Cartridge
Technical Support
Memphis, TN (888) 757-0762
Nashua, NH (888) 833-5727
10.
After removing the developer roller side
plate, remove the developer roller by pulling
the shaft through the area that was covered
by the stabilizer plate.
NOTE: Be sure to remove the developer
roller drive gear from the geared side of the
cartridge before sliding the roller out.
11.
To remove the OPC, simply push it up
from the bottom of the cartridge and pull it
out the top. To maintain optimum print
quality and reliability, it is recommended to
change it out each cycle.
12. After removing the OPC, finish cleaning
the toner hopper area.
NOTE: Pay careful attention to the sponge
toner delivery roller in the toner hopper.
Manually rotate this roller during the
cleaning process to ensure that all of the old
toner is removed from the sponge roller.
13. You can clean any toner from the
working edge of the blade with a Q-tip.
Fig. 9
Fig. 10
NOTE:
It is
not
recommended to remove
the Doctor Blade during the remanufacturing
process. Removal can cause damage to the
sealing foams.