5) No defrosting
1. Even though both F·R-defrost sensors short-circuit, normal operation continues without
defrosting.(Refer to self-diagnosis function)
2. Even though the temperature fuse is off, there is no heating but defrosting natural
temperature increase comp off-time takes longer.
3. Even though both F·R-defrost sensor are open, heating does not end and comp-off
maintains with temperature fuse short-circuited.(Refer to self-diagnosis function)