Samsung RFG298AARS Especificações Página 92

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 91
91
TROUBLESHOOTING
Start
Is the confirming sound of
the valve operation heard when
Ice maker(F) test switch pushed?
Does Main PCB MICOM
#58 have high (5V)output?
Does Main PCB IC72
#18 have about 0.7V
output?
Is the contact point of main
PCB RELAY RY76 normal?
MAIN PCB normal
-- Need to check the other parts
Check the wire between Ice
water valveMAIN PCB
Ice water valve itself has trouble
or bad contact of connector
Check the connection hose
Normal(Check Ice
water valve hose)
Check soldering
short/Replace PCB
Check soldering
short/Replace PCB
Check soldering
short/Replace PCB
Typical PCB Ground REG1 Heater Sink
Checking method of voltage Based on
PCB typical Ground REG1 Heater Sink
1) Check the voltage of IC72#1(same voltage
as IC01#58)
- ICE Water valve operating (about 5V±0.5V)
Based on PCB typical Ground REG1 Heater Sink
2) IC72 #18 voltage
- ICE Water valve Waiting (about 13V±0.8V)
- ICE Water valve operating (about 0.7V±0.5V)
3) Check the voltage of Fridge Ice Water Valve
operating(AC voltage)
=> For checking the Relay RY76
CN70-"9"(Red) CN72-"5"(Brown)
- ICE Water valve waiting (about AC 0V)
- ICE Water valve operating (about AC 115V ± 20%)
2) Freeze Ice Water valve(Dual Ice Maker)