Vivaldi MAX_AQN09VFU@@ IB&IM_32163A-3_EN.indd 1 2015/8/17 14:47:25

Página 2 - Contents

10Basic operation is an operation mode that can be selected by pressing the Mode button. AutoIn Auto mode, the air conditioner will automatically set

Página 3

11ENGLISHPress the button to turn on the air conditioner.Press the button to set the operating mode.• EachtimeyoupresstheMode button, the mo

Página 4

12Adjusting the air ow directionAir ow can be directed to your desired position.Turbo function will be helpful to cool your room quickly and eectiv

Página 5 - FOR CLEANING

ENGLISH13 modeFor a comfortable sleep, the air conditioner will operate it Fall asleep  Sound sleep  Wake up from mode.1. Press the button on t

Página 6 - Checking before use

14Setting the On/O timerYou can set the air conditioner to turn on/o automatically at desired time. Setting On timer while the air conditioner is o

Página 7 - Main parts

ENGLISH15Combining On Timer and O TimerIf the air conditioner is on If the air conditioner is oPreset time on On timer is longer than O timerEx) On

Página 8 - Remote controller buttons

16Auto clean function will prevent from growing mold by eliminating the moisture inside of the indoor unit. Your indoor unit evaporates the moisture i

Página 9 - Remote controller display

ENGLISH17Cleaning the air conditionerCleaning the indoor unitCleaning the outdoor unit heat exchangerOpening the panel Wipe the surface of the unit

Página 10 - Basic function

18Cleaning the air conditionerRemoving the Air lterGrab the handle and lift it up. Then, pull the Air lter towards you and slide it down. Air lterC

Página 11

ENGLISH19Maintaining the air conditionerIf the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it

Página 12 - Using the Turbo function

2Cool Summer OerOn those hot sweltering summer days and long restless nights, there is no better escape from the heat than the cool comforts of home.

Página 13

20TroubleshootingRefer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses.PROBLEM SOLUTION

Página 14 - Setting the On/O timer

21ENGLISHPROBLEM SOLUTIONError is indicated. • When an indoor unit indicator blinks, contact the nearest service center.Noise is generated. • Depe

Página 15

22Carefully follow the precautions listed below because they are essential to guarantee the safety of the equipment.•Alwaysdisconnecttheaircondi

Página 16 - Using the Auto Clean function

ENGLISH23Installing the unitIMPORTANT:Wheninstallingtheunit,alwaysremembertoconnectrsttherefrigeranttubes,thentheelectricallines. A

Página 17 - Cleaning the air conditioner

24Outdoor Unit Where it is not exposed to strong wind Well ventilated and dustless places Out of the direct sunlight and rainWhere neighbors a

Página 18

25ENGLISHSpace Requirements for Outdoor UnitWhen installing 1 outdoor unitWhen installing more than 1 outdoor unit11.8 or more When the air outlet i

Página 19 - Periodical checks

26Choosing the installation location(Unit:inch) When the upper part of the outdoor unit and the air outlet is opposite the wall When the walls a

Página 20 - Troubleshooting

ENGLISH27The following connection accessories are optional. If they are not supplied, you should obtain them before installing the air conditioner.Opt

Página 21

28Fixing the installation plateWall<0.79inch(20mm)Plastic Anchor2. Fix the indoor unit.If you x the indoor unit on a wall (1) Fix the installat

Página 22 - Safety precautions

ENGLISH292 . Open the front grille.3 . Remove the screw securing the connector cover.4 . Pass the assembly cable through the rear of the indoor uni

Página 23 - Indoor unit

ENGLISH3Safety precautionsUSING PARTSBefore using your new air conditioner, please read this manual thoroughly to ensure that you know how to safely a

Página 24 - Outdoor Unit

30Connecting the assembly cable• Endofthewiremustbecircular.• Afterconnectingthecables,makesureterminalnumbersontheindoor/outdoorun

Página 25

ENGLISH314. Cut o the remaining foam insulation. 5. If necessary, bend the pipe to t along the bottom of the indoor unit. Then pull it out throug

Página 26 - Accessories

32Cutting or extending the pipeIndoor outlet pipe Connecting pipeFlare nut5. Check if you ared the pipe correctly (see examples of incorrectly ared

Página 27 - Fixing the installation plate

ENGLISH33Installing and connecting the drain hose of the indoor unitWallIndoor unitDrain hoseThe drain hose must NOT slant upwards. The end of the dr

Página 28 - Connecting the assembly cable

34Installing and connecting the drain hose of the indoor unit• Thehosewillbexedpermanentlyintopositionafternishingtheinstallationandt

Página 29 - Outdoor unit

ENGLISH35Installing and connecting the drain hose of the outdoor unitFrameGroundEstimated snow fallSnow-proof hoodBottom surface of outdoor unitDrain

Página 30

36Purging the connected pipes3. Connect the charging hose of the low-pressure side of manifold gauge to a gas service port as seen in the picture.4.

Página 31 - Purging the indoor unit

37ENGLISHRefrigerant type GWP valueR-410A 1975 GWP=Global Warming PotentialIndoor unitOutdoor unit= ( ) kg= ( ) kg+= ( ) kgContains uorinate

Página 32

38AAPerforming the gas leak testsLeak test with nitrogen (before opening valves) In order to detect basic refrigerant leaks, before recreating the vac

Página 33 - Drain hose installation

ENGLISH39AAFixing the indoor unit in placeInsulationPipes'X'Rubber leg'Y'Perform the following work on the area where gas leak tes

Página 34 - Drain pan outlet

4Safety precautionsFOR POWER SUPPLYWARNINGRemove all foreign substances such as dust or water from the power plug terminals and contact points using a

Página 35 - Purging the connected pipes

40AAFinal Check and Trial OperationTo complete the installation, perform the following checks and tests to ensure that the air conditioner operates co

Página 36

ENGLISH41AA Items to prepare (compressor and insulation tape should be prepared by an installation technician.)1. As shown in the gure, peel o

Página 37

42Sub PCB installation(optional)(Wried remote controller, central remote controller etc.)1. Turn the power o and tightly grab top of the front panel

Página 38 - Performing the gas leak tests

ENGLISH43Remocon module installation (optional)Components partsDescriptionRAC SUB PBA - Wired Remote Controller Wire ConnectionProduct name RAC-SUB PB

Página 39

QUESTIONS OR COMMENTS?COUNTRY CALL OR VISIT US ONLINE ATU.S.A - Consumer Electronics1-800-SAMSUNG(726-7864) www.samsung.com/us/supportU.S.A - Mobile P

Página 40

AQ09VFU SeriesAQ12VFU SeriesAQ18VFU SeriesAQ24VFU SeriesAQ36VFU SeriesAir Conditioneruser & installation manualimagine the possibilities

Página 41

5ENGLISHFOR USINGWARNINGDo not place an object near the outdoor unit that allows children to climb onto the machine. This may result in children ser

Página 42

6Operation rangesThe table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for eci

Página 43 - 12V COM2

ENGLISH7Main partsDisplayYour air conditioner may slightly look dierent from illustration shown above depending on your model.Checking the name of th

Página 44 - QUESTIONS OR COMMENTS?

8Checking the remote controllerRemote controller buttons• Pointtheremotecontrollertowardstheremotecontrollerreceiveroftheindoorunit.• W

Página 45 - Air Conditioner

9ENGLISHRemote controller display• Thesignalmaynotbereceivedwellofelectroniclightingstyleuorescentlampssuchasinverteruorescentlam