ENGLISH
E-
13
Completing the Installation
Performing the Gas Leak Tests
Fixing the Indoor Unit in Place
You must check if there is a gas leak before completing all the installation process.
(connecting the assembly pipe and hose between indoor unit and outdoor unit,
insulating the cables, hose and pipe, and fixing the indoor unit to the installation plate)
To check for gas leaks on the... Using a leak detector, check the...
Indoor unit Flare nuts at the end of sections
C and D.
Outdoor unit Valves on sections A and B.
C
D
A
B
Installation plate
1 To avoid condensation problems, place heat-resistant polyethylene foam separately around
each refrigerant pipe in the lower part of the indoor unit.
2 Wrap the refrigerant pipe and the drain hose in the rear of the indoor unit with the
absorbent pad.
Wind the pipe and hose three times to the end of the indoor unit with the absorbent
pad. [ inch(20mm) interval]
3 Wind the pipe, assembly cable and drain hose with insulation tape.
4 Place the bundle (the pipe, assembly cable and drain hose) in the lower part of the
indoor unit carefully so as not to be projected from the rear of the indoor unit.
5 Hook the indoor unit on the installation plate and move the unit to the right and left
until it secures in place.
6 Wrap the rest of the pipe with vinyl tape.
7 Attach the pipe to the wall using clamps (Optional).
After checking for a gas leak in the system, you can insulate the pipe,
hose and cables. Then place the indoor unit on the installation plate.