Samsung AM018FN2DCH/TC Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Aparelhos de ar condicionado "split system" Samsung AM018FN2DCH/TC. Samsung AM024FN2DCH/TC Installation guide Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1

2way_cassette_IM_03949A-03_CO_EN.indd 2 2014-08-29 오후 4:12:37

Página 2 - Air Conditioner

9ENGLISHDeciding on where to install the indoor unitDrawing of the indoor unitUnit : mm (inch)890 (35)919 (36.2)919 (36.2)650 (25.6) 493 (19.4)72.5 (2

Página 3 - Contents

10Indoor unit installationIt is recommended to install the Y-joint before installing the indoor unit.1. Place the pattern sheet on the ceiling at the

Página 4 - Safety precautions

11ENGLISH6. Adjust the height of the indoor unit by using the gauge of dimensions.• You should adjust the gauge of dimensions and the pattern sheet

Página 5

12Connecting the refrigerant pipeThere are two refrigerant pipes of different diameters : A smaller one for the liquid refrigerant A larger one for

Página 6

13ENGLISHCutting/aring the pipes1. Make sure that you prepared the required tools. (pipe cutter, reamer, flaring tool and pipe holder)2. If you want

Página 7 - Accessories

14Performing leak test & insulationLeak testLEAK TEST WITH NITROGEN (before opening valves)In order to detect basic refrigerant leaks, before recr

Página 8 - 1500 (59) or more

15ENGLISH5. Select the insulation of the refrigerant pipe.• Insulate the gas side and liquid side pipe referring to the thickness according to the p

Página 9 - Insulation guide

16Performing leak test & insulationRefrigerant pipe before EEV kit and MCU or without EEV kit and MCU You can contact the gas side and liquid si

Página 10 - Drawing of the indoor unit

17ENGLISHDrain pipe and drain hose installationCare must be taken when installing the drain pipe and drain hose for the indoor unit so that condensate

Página 11 - Indoor unit installation

18Drain pipe and drain hose installationDrain pipe connection1. The drain pipe should be installed within 100 mm(4”) from the flexible hose, lift up f

Página 12 - Purging the unit

Cassette Type Series2 Way cassette : AM✴✴✴FN2DCH✴Air Conditionerinstallation manualimagine the possibilitiesThank you for purchasing this Samsung prod

Página 13

19ENGLISHCentralized Drainage1. Install main air vent at the front of the farthest indoor unit from the main drain when installed indoor units are mo

Página 14 - Cutting/aring the pipes

20Wiring workPower and communication cable connection1. Before wiring work, you must turn off all power source.2. Indoor unit power should be supplie

Página 15 - Insulation

21ENGLISHSelecting compressed ring terminalSilver solderNorminal dimensions for cable [mm2 (inch2)] 1.5 (0.002) 2.5 (0.003) 4 (0.006)Norminal dimensio

Página 16

22Wiring workSpecication of electronic wirePower supply MCCB ELB Power cable Earth cable Communication cableMax : 242VMin : 198VXAXA, 30 mmA0.1 s2.5

Página 17

23ENGLISH  Calculation• Installing with 1 sort wire.220[V]-2.2[V]-2.0[V]····· 2.5[mm2](0.003inch2) ·····208.8[V](Within 198 V~242 V)-(2.2+2.0+1.

Página 18

24Setting an indoor unit address and installation optionSet the indoor unit address and installation option with remote controller option. Set the eac

Página 19 - Drain pipe connection

25ENGLISHStep 1. Entering mode to set option1. Remove batteries from the remote controller.2. Insert batteries and enter the option setting mode whi

Página 20 - Centralized Drainage

26Setting an indoor unit address and installation optionOption setting Status1. Setting SEG2, SEG3 optionPress Low Fan button(∨) to enter SEG2 value

Página 21 - Wiring work

27ENGLISHOption setting Status12. Setting Cool mode Press Mode button to be change to Cool mode in the OFF status.13. Setting SEG16, SEG17 optionPres

Página 22 - Silver solder

28Setting an indoor unit address and installation optionSetting an indoor unit address (MAIN/RMC)1. Check whether power is supplied or not. - When th

Página 23

2ContentsSafety precautions ... 3Accessories ...

Página 24 - Tightening torque

29ENGLISHSetting an indoor unit installation option (suitable for the condition of each installation location)1. Check whether power is supplied or n

Página 25

30Setting an indoor unit address and installation option02 series installation option(Detailed)Option No. : 0AXXXX-1XXXXX-2XXXXX-3XXXXXOption SEG1 S

Página 26

31ENGLISHOption SEG19 SEG20 SEG21 SEG22 SEG23 SEG24Explanation PAGEIndividual control of a remote controllerHeating setting compensationEEV Step of s

Página 27

32Setting an indoor unit address and installation option05 series installation optionSEG1 SEG2 SEG3 SEG4 SEG5 SEG60 5Use of auto change over for HR on

Página 28

33ENGLISHOption SEG7 SEG8 SEG9 SEG10 SEG11 SEG12Explanation PAGE(When setting SEG3)Standard for mode change Cooling  Heating(When setting SEG3)Time

Página 29 - Indoor Unit

34Setting an indoor unit address and installation optionChanging a particular optionYou can change each digit of set option.Option SEG1 SEG2 SEG3 SEG

Página 30 - 02 series installation option

35ENGLISHFinal checks and user tipsTo complete the installation, perform the following checks and tests to ensure that the air conditioner operates co

Página 31

36TroubleshootingDetection of errors If an error occurs during the operation, an LED flickers and the operation is stopped except the LED. If you r

Página 32

37ENGLISHAbnormal conditionsError codeLED lamp displayGreen Red1. COND mid sensor is detached E241× ×◑ ◑ ◑2. Refrigerant leakage (2nd detection) E5543

Página 33 - 05 series installation option

3ENGLISHSafety precautionsCarefully follow the precautions listed below because they are essential to guarantee the safety of the equipment.WARNING•

Página 34

4Safety precautionsInstalling the unitIMPORTANT: When installing the unit, always remember to connect first the refrigerant tubes, then the electrical

Página 35 - Changing a particular option

5ENGLISH• Make sure that you earth the cables. - Do not connect the earth wire to the gas pipe, water pipe, lighting rod or telephone wire. If earthi

Página 36 - Final checks and user tips

6AccessoriesThe following accessories are supplied with the indoor unit.The type and quantity may differ depending on the specifications.Pattern sheet I

Página 37 - Troubleshooting

7ENGLISHSpace requirements for indoor unit1500 (59) or more1500 (59) or more1500 (59) or more1500 (59) or moreUnit : mm (inch)• The units must be ins

Página 38

8Selecting the installation locationInsulation guideAECBDUnit : mm (inch)880 (34.6)570 (22.4)185 (7.3)  Thickness: more than 10 (0.4)Unit : mm (inch)

Comentários a estes Manuais