
2 . Open the cover panel.
3 . Remove the screw securing the connector cover.
4 . Pass the assembly cable through the rear of the indoor unit and connect the assembly cable to terminals.
(Refer to the picture below)
• Eachwireislabeledwiththecorrespondingterminalnumber.
5 . Pass the other end of the cable through the 65 mm hole in the wall.
6 . Close the connector cover by tightening the screw carefully.
7 . Close the cover panel.
8 . Remove the terminal board cover on the side of the outdoor unit.
9. Connect the cables to the terminals as seen in the picture.
• Eachwireislabeledwiththecorrespondingterminalnumber.
Indoor unit
Outdoor unit
• Alsocircularterminalmustbematchedwithscrewsizeinterminalblock.
• Afterconnectingthecables,makesureterminalnumbersontheindoor/outdoorunitmatches.
• PleaseensurethatPower&Communicationcablesareseparated,theymustnotbeinthesamecable.
10. Connect the grounding conductor to the grounding terminals.
11. Close the terminal board cover by tightening the screw carefully.
• InRussiaandEurope,consultwiththesupplyauthoritytodeterminethesupplysystemimpedancebefore
installation.
• Connectthewiresrmlysothatwirescannotbepulledouteasily.
(If they are loose, it could cause burn-out of the wires.)
• Connectthewiresaccordingtocolorcodes,referringtothewiringdiagram.
• Thepowercableandtheinterconnectioncableshouldbeselectedaccordingtothespecicationinpage35~36.
Indoor unit
Outdoor unit
31
2
31
2
1(L) 2(N) 3(C)
1(L) 2(N) 3(C)
Ground wire
(Green/Yellow)
Ground wire
(Green/Yellow)
Connecting the assembly cable
English-36
Comentários a estes Manuais