INITIALIZATION
FORCED INITIALIZATION WITH EXTERNAL LINE
Turn off the product, shortcircuit between the green line and
the orange line with white stripes, and turn it back on.
When the initialization is completed, 3 LED indicators are
blinking with a beep.
Restore the connection of the two lines back to their original
state.
HARDWARE FORCIBLE INITIALIZATION
This is to initialize the product forcibly by disassembling it.
Use this method only if you have lost the Master Card or the password, or if the forcible initialization with the external line
failed.
Turn off the product and detach it from the installation site, then loosen the screw (x4) on each corner to
disassemble it as shown.
Apply power to the product and short-circuit the jumper for
one second as shown.
When the initialization is completed, 3 LED indicators are
blinking.
Turn off the product and restore it to the original installation state.
1.
2.
3.
1.
2.
3.
4.
X Y Z
[ \ ]
^ _ `
lzj lu{
W
i
zzhTzYWWW
12V
GND
Green
Orange with white stripes
Connect
(Short-
circuit)
Connect
(Short-circuit)
Vista de página 16