1-4 Einrichten der DIP-Schalter
1-4-1 Serielle Schnittstelle
• DIP Switch 1
SW Function ON OFF Default
1-1 Auto Line Feed Enable Disable OFF
1-2 Handshaking XON/XOFF DTR/DSR OFF
1-3 Data Length 7bits 8bits OFF
1-4 Parity Check Yes No OFF
1-5 Parity Selection EVEN ODD OFF
1-6 OFF
1-7 ON
1-8
Baud Rate Selection
(bps)
Refer to the following table 1
OFF
• DIP Switch 2
SW Function ON OFF Default
2-1 Reserved - - OFF
2-2 Bell Disable Enable OFF
2-3 Auto Cutter Disable Enable OFF
2-4 BUSY Condition Receive Buffer Full
* Offline
* Receive Buffer
Full
OFF
2-5 OFF
2-6 OFF
2-7
Print Density Refer to the following table 2
OFF
2-8 Reserved - - OFF
1-4-2 Parallel- und USB2.0-Schnittstelle
• DIP Switch 1
SW Function ON OFF Default
1-1 Auto Line Feed Enable Disable OFF
1-2
~
1-8
Reserved - - OFF
• DIP Switch 2
SW Function ON OFF Default
2-1 Reserved - - OFF
2-2 Bell Disable Enable OFF
2-3 Auto Cutter Disable Enable OFF
2-4 BUSY Condition Receive Buffer Full
* Offline
* Receive Buffer
Full
OFF
2-5 OFF
2-6 OFF
2-7
Print Density Refer to the following Table 2
OFF
2-8 Reserved - - OFF